Warning: this site contains 0% fragrance

The fragrance facts, graded

Don’t take our word for it. Here’s every fact on this site, with its evidence grade, its caveats, and a link to the source, so you can check us.

We start you on the strong ones: findings that have been replicated or come from one large, well-controlled study. Moderate and weak facts are here too, labeled for what they are. Use “Link to this fact” to share a single card.

19 facts match “allergy”

Skin allergy / Review of other studies

EU scientific advisers (SCCS 2012) list 82 fragrance ingredients as established causes of skin allergy in people.

Strong evidence.

Caveats

Primary now ingested (SCCS/1459/11): 82 = 54 single chemicals + 28 natural extracts on clinical evidence alone, including the 26 labeled in 1999; the count measures reported allergy evidence, not safety.

Source: Kumar 2020 (SCCS 2012), Journal of Cosmetic Dermatology Link to this fact

Skin allergy / Measured in people or real products

The fragrance chemicals most often found in household products were mostly not in the standard fragrance-allergy patch test used at the time: 6 of its 8 chemicals were in 12% of products or fewer.

Strong evidence.

Caveats

Frequency in products is not the same as clinical sensitization rate; FM II and hydroperoxide testing later added. Clinically confirmed in Heydorn et al. 2003 (n=658 hand-eczema patients, 3 centers): only 3 of the 14 chemicals selected from this paper's household-product survey were FM I constituents, and FM I caught only 45.5% of the fragrance-allergic patients (5.6% of all patients tested missed). The exposure-frequency leader, limonene (78% of products), caused only 0.8-0.9% oxidized-limonene reactivity clinically — product frequency of a chemical still does not predict its clinical allergy rate.

Source: Rastogi 2001, Contact Dermatitis Industry-funded Link to this fact

Skin allergy / Measured in people or real products

Common scent chemicals such as linalool hardly cause allergy when fresh, but once exposed to air they form new chemicals that do: in 1,511 dermatitis patients at six European clinics, 1.3% were allergic to air-oxidized linalool (later studies with a stronger test found about 7%).

Strong evidence.

Caveats

Dermatitis patients, not general population; 2005 test concentration (2.0% pet.) was later shown too low. Clinical relevance no longer just inferred: Andersch Björkman 2014 (ROAT) shows patients identified this way go on to develop dermatitis from twice-daily use of a cream/perfume containing oxidized linalool at concentrations as low as 0.3% (0.056% linalool hydroperoxides, ~27 µg/cm²) — inside the 0.1–2% range measured for individual fragrance ingredients in real products.

Source: Matura 2005, Contact Dermatitis Link to this fact

Skin allergy / Measured in people or real products

Fresh limonene and linalool rarely cause allergy; the allergens form when these chemicals react with air, which also happens in essential oils and perfumes during storage.

Strong evidence.

Caveats

A '0.1-0.3% of patients' figure was removed because it does not trace to a source in our evidence base. Parent-compound sensitization rates are low but vary by dataset; see the Dittmar 2019 entry for oxidized-terpene positive rates.

Source: Bråred Christensson 2016, Contact Dermatitis Industry-funded Link to this fact

Skin allergy / Measured in people or real products

60.5% of patients allergic to oxidized linalool would never have learned they had a fragrance allergy from the standard fragrance patch tests.

Strong evidence: Dermatitis patients.

Source: Christensson 2012, Contact Dermatitis Link to this fact

Skin allergy / Review of other studies

Standard allergy tests with fresh limonene and linalool miss most of these allergies, so European experts now recommend adding the oxidized forms to routine patch testing.

Strong evidence.

Source: Ogueta 2022, Contact Dermatitis Link to this fact

Skin allergy / Review of other studies

Scent chemicals such as limonene and linalool rarely cause skin allergy when fresh, but once exposed to air they form much stronger allergens; products and oils kept open or stored a long time can contain more of them.

Strong evidence.

Caveats

Review of experimental and clinical work; no new data. Hydroperoxide content depends on storage, light, air exposure and antioxidants; no study here shows that a product's age alone predicts content, so do not claim 'older means worse'.

Source: Karlberg & Lepoittevin 2021, Contact Dermatitis Link to this fact

Skin allergy / Measured in people or real products

After nickel, the standard fragrance allergy test (Fragrance Mix I) was the most common positive in the general population: about 3.5% reacted, across 19 studies and 19,440 people.

Strong evidence: Pooled 1966-2017 (CI 2.1-5.4%); the largest modern study found 1.8-2.6% for the same test.

Source: Alinaghi 2018, Contact Dermatitis Link to this fact

Skin allergy / Review of other studies

The standard fragrance patch test covers only 8 of the 82 fragrance chemicals known to cause allergy in people, so any single test undercounts fragrance allergy.

Strong evidence: Authors' discussion; oxidized limonene/linalool never tested in a general-population sample.

Source: Alinaghi 2018, Contact Dermatitis Link to this fact

Skin allergy / Measured in people or real products

Among about 4,100 North American patients referred for allergy patch testing in 2019–2020, 12.8% reacted to the standard fragrance mix and 11.1% to oxidized linalool, both among the ten most common skin allergens and both up from 2017–2018.

Strong evidence: Referral population, not the general public; primary is DeKoven 2023 (NACDG), cited by the review.

Source: Rodriguez 2024, Cutis Link to this fact

Skin allergy / Measured in people or real products

The industry's safety panel cleared linalool, a lavender-scented chemical in most fragranced products, as raising 'no safety concerns' after testing the fresh chemical; independent clinics later found that air-exposed (oxidized) linalool causes allergic reactions in about 7% of patients patch-tested for skin allergy (2,900 patients in 9 centers; 5,773 in Sweden, with rates rising).

Strong evidence: Clinic rates are in dermatitis patients, not the general population; test preparations debated; fresh linalool is genuinely a weak sensitizer.

Source: Bickers 2003 (RIFM Expert Panel), Regulatory Toxicology and Pharmacology Industry-funded Link to this fact

Skin allergy / Measured in people or real products

In a patch test of 3,119 people randomly sampled from the general population of five European countries, 2.6% tested positive to fragrance mix I and 1.9% to fragrance mix II, and 1.9% had a fragrance allergy judged clinically relevant (skin symptoms plus product avoidance).

Strong evidence.

Caveats

The largest, best-controlled general-population fragrance patch-test study to date (n=3,119 of 12,377 interviewed, harmonized protocol across 5 countries); the raw marker-positive rate is higher (4.1%) before the clinical-relevance filter, and about half of marker-positive people do not meet the stricter definition.

Source: Diepgen 2015 (EDEN), British Journal of Dermatology Industry-funded Link to this fact

Skin allergy / Measured in people or real products

In a 5-year Danish patch-test survey of 17,716 eczema patients, 10.1% had fragrance allergy, and cosmetic products caused 42.1% of it; deodorants (25.3% of specific products listed) and scented lotions (24.4%) were the two leading culprits, together accounting for roughly half of all cases.

Strong evidence.

Caveats

Clinic-referred eczema patients (Danish Contact Dermatitis Group members' consecutive patients), not a general-population sample; retrospective database analysis, not a prospective cohort.

Source: Heisterberg 2011, Contact Dermatitis Link to this fact

Skin allergy / Measured in people or real products

Deodorants were significantly more likely to be the reported cause of fragrance allergy in men than women (37.9% vs 21.1% of listed products, odds ratio 2.3), while scented lotion (odds ratio 2.6) and fine fragrances (odds ratio 4.2) were significantly more often the reported cause in women; shampoo showed no sex difference.

Strong evidence: Reflects differential product use by sex, not necessarily differential susceptibility to sensitization.

Source: Heisterberg 2011, Contact Dermatitis Link to this fact

Skin allergy / Measured in people or real products

Standard fragrance allergy screening tests (the fragrance mixes, HICC, Myroxylon pereirae, colophonium) missed about 70% of patients allergic to oxidized limonene or linalool; only 30-33% of hydroperoxide-allergic patients also reacted to any standard baseline marker.

Strong evidence: None.

Source: Deza 2016, Contact Dermatitis Industry-funded Link to this fact

Skin allergy / Measured in people or real products

Women's overall contact allergy rate (35.5%) was roughly double men's (17.1%) in this general-population sample.

Strong evidence: OR 2.6 (95% CI 2.1-3.1) adjusted for age and skin complaints; nickel allergy (much more common in women, 22.2% vs 5.2%) drives most of the gap.

Source: Diepgen 2016 (EDEN), British Journal of Dermatology Industry-funded Link to this fact

Skin allergy / Measured in people or real products

In a 2018 meta-analysis pooling 28 general-population patch-test studies (20,107 people), the pooled prevalence of contact allergy to Myroxylon pereirae (balsam of Peru) was 1.8% (12 studies, 8,002 people, 95% CI 1.0-2.7%).

Strong evidence.

Caveats

Meta-analysis with substantial heterogeneity across the 12 pooled studies (I2 85.3%); general-population samples, not clinic-referred dermatitis patients, so this is a lower-bound estimate compared to referred populations.

Source: Alinaghi 2018, Contact Dermatitis Link to this fact

Skin allergy / Government agency

In 2012 the EU's scientific committee on consumer safety (SCCS) classified 82 fragrance ingredients (54 chemicals and 28 natural extracts, including all 26 then labeled) as established causes of contact allergy in people, on clinical evidence alone.

Strong evidence.

Caveats

Counts reported patch-test and case-report evidence from the literature to October 2010; many counts rest on small or single-center series and publication bias; the classification measures allergy evidence, not a safe-use verdict.

Source: SCCS 2012 (SCCS/1459/11) Link to this fact

Information, not medical advice. See also: myths we won’t tell you.