Indoor air / Measured in people or real products

The isocyanic acid released by incense tracked its precursor hydrogen cyanide almost exactly as in open biomass burning (emission ratio 0.18, within the 0.16-0.50 range reported for wildland fires), showing incense combustion runs on the same pyrolysis chemistry as biomass burning.

Moderate evidence: One incense product; mechanism (HCN to HNCO conversion pathway) inferred from correlation, not independently confirmed.

Source: Deng 2026, Environment International Link to this fact

Indoor air / Measured in people or real products

Incense smoke was far more chemically complex than candle smoke: over 100 distinct VOCs, including classic wood-smoke markers (acetonitrile, methoxyphenols) and a set of nitrogen-ring compounds (pyrroles) that were completely absent from either candle's emissions.

Moderate evidence: One incense brand vs. one scented and one unscented candle product.

Source: Deng 2026, Environment International Link to this fact

Indoor air / Measured in people or real products

During morning stir-frying, oxygenated aldehydes (formaldehyde, acetaldehyde, acetone, butanal) surged to 19.38 ppb, 91% of the total measured aldehyde signal, and on a sunny day these aldehydes rebounded upward again shortly after the stove was turned off and the hood closed, tracking a sharp rise in sunlight-driven hydroxyl radical (OH) production rather than continuing to decline.

Moderate evidence.

Caveats

Single home, comparative (non-replicate) cooking scenarios; the authors state that physical transport of pollutants from kitchen to sampling point could not be fully separated from chemical production because human occupancy ruled out using CO2 as a transport tracer.

Source: Deng 2026, Environment International Link to this fact

Indoor air / Measured in people or real products

Frying with peanut oil (29.1% linoleic acid) produced more oxidized volatile byproducts than frying with olive oil (5.01% linoleic acid), consistent with peanut oil's greater share of double bonds available for hydroxyl-radical attack.

Moderate evidence: Single comparative cooking session per oil, not replicated; ingredients also differed between sessions.

Source: Deng 2026, Environment International Link to this fact

Indoor air / Measured in people or real products

Ammonia, a byproduct rarely discussed for indoor combustion, rose 3-9 ppb above background during candle and incense burning (to 30-38 ppb total) and 4-10 ppb above background during cooking (to 30-44 ppb total), in both cases a statistically significant increase over pre-combustion levels.

Moderate evidence: Single-home measurements; cooking-related ammonia rise could not be cleanly separated from concurrent human-occupancy ammonia emissions.

Source: Deng 2026, Environment International Link to this fact

Indoor air / Other evidence

Burning scented candles releases VOCs, SVOCs, and particulate matter, including polycyclic aromatic hydrocarbons (benzo[a]pyrene, naphthalene, anthracene, pyrene) classified as carcinogenic.

Moderate evidence.

Caveats

This is a secondhand restatement in a two-page opinion piece, not a new measurement; our own chamber primaries (Salthammer 2021, Andersen 2021) independently confirm PAH/VOC output but find it strongly formulation-dependent rather than universal to all scented candles.

Source: Singh 2023, Environmental Science & Technology Link to this fact

Indoor air / Other evidence

In a small case series, removing mothballs and reducing scented cleaning/personal-care products, candles, and stored chemicals cut targeted indoor-air VOC categories by roughly a quarter to over 95% (e.g., naphthalene from mothballs down 96%, p-dichlorobenzene from moth crystals down 56-80%, odorants/fragrances down 26-80%) across three homes, measured by GC/MS air sampling before and after a structured home intervention.

Moderate evidence.

Caveats

Small, uncontrolled, non-blinded case series with multiple co-occurring intervention elements per home (product substitution, education, counseling, and in one case new chemical storage); cannot isolate the VOC-reduction effect from other changes.

Source: Rincón et al. 2024, Primary Health Care Research & Development Link to this fact

Indoor air / Measured in people or real products

In a 1989 NASA/ALCA interim study, sealed small chambers (0.69-0.87 m3) each holding one potted plant received a single one-time dose of benzene, trichloroethylene, or formaldehyde; over the next 24 hours, removal of that single chemical ranged from about 0% up to about 70%, depending on plant species and chemical.

Moderate evidence: Sealed chamber, zero air exchange, single pulse dose of one chemical, 24h, one plant per chamber; not a real room and the report does not claim it is.

Source: Wolverton 1989 Link to this fact

Indoor air / Measured in people or real products

General-population indoor air generally has higher styrene concentrations than outdoor air (residential surveys in the range of roughly 0.3-1.5 micrograms per cubic meter, vs. under 1 ppb / about 4.3 micrograms per cubic meter outdoors), with off-gassing from styrene-containing household products contributing to the indoor level.

Moderate evidence: Multiple national surveys (Canada, Finland, France, Germany, USA) show a fairly consistent range, but sources of indoor styrene were not quantitatively apportioned in most studies.

Source: IARC 2019 (Vol. 121) Link to this fact

Indoor air / Government agency

The US EPA states there is currently no evidence that a reasonable number of houseplants remove significant quantities of pollutants in homes and offices, even though houseplants have been shown to reduce levels of some chemicals in laboratory experiments.

Moderate evidence: A denial of the real-room extrapolation, not a measurement; EPA cites no specific study for either the lab result or the real-room gap.

Source: US EPA, "The Inside Story" (accessed 2026-09-28) Link to this fact

Indoor air / Animal study

In a mouse inhalation bioassay, repeating the same 1-hour exposure to fabric-softener-B emissions three times over 24 hours (concentration held constant, ~250 ppm TVOC) roughly doubled the sensory-irritation response, from 22% of breaths at the first exposure to 52% at the second and 47% at the third, while sham (clean-air) exposures stayed under 10% throughout.

Moderate evidence.

Caveats

Single, unreplicated commercial testing laboratory (the study authors' own firm); mouse data only, no measured breathing-zone concentration comparable to household air; an independent lab (Tepper 1995) failed to reproduce this lab's mouse findings for a different product class (carpets).

Source: Anderson & Anderson 1999, Toxicology and Industrial Health Link to this fact

Indoor air / Animal study

The same repeated-exposure escalation appeared with vinyl mattress-cover emissions (Brand B: 22% to 46% to 96% of breaths showing sensory irritation over three exposures) and disposable-diaper emissions (Brand B: 20% to 32% to 84%), in mice.

Moderate evidence.

Caveats

Single-lab, unreplicated mouse data; brands A, D and F mattress covers showed smaller, less consistent increases (exact values available only from the paper's figure, not the text); no comparison to measured indoor concentrations of these products.

Source: Anderson & Anderson 1999, Toxicology and Industrial Health Link to this fact

Indoor air / Animal study

Not every irritating mixture became more irritating with repetition: a different fabric-softener brand (A) and a solid air freshener produced strong sensory irritation at every exposure but showed no increasing trend over three to six repeat exposures, and GC/MS analysis found almost no chemical overlap between the mixtures that did and did not show the escalating effect.

Moderate evidence: The paper could not identify which chemical(s) drive the sensitizing effect; mouse data only, single unreplicated lab.

Source: Anderson & Anderson 1999, Toxicology and Industrial Health Link to this fact

Indoor air / Animal study

Air brought from a federal office building under litigation for poor indoor air quality (carried to the lab in sealed bags) caused the same objective sensory-irritation signature in mice as the consumer-product tests, dropping their respiratory rate to about 46% of baseline before partial recovery; air from buildings people considered acceptable did not cause this effect.

Moderate evidence: Single building, single lab, one comparison air sample; the underlying human complaints were not independently verified against objective health measures in this paper.

Source: Anderson & Anderson 1999, Toxicology and Industrial Health Link to this fact

Indoor air / Measured in people or real products

Modeled deposited aerosol dose from a single one-minute use of a consumer spray varied by about four orders of magnitude across 10 tested products (roughly 0.1 to 1,335 nanograms per kg body weight), and for most products (8 of 10) about 85-88% of the deposited aerosol mass landed in the head airways (nose/throat) rather than deeper in the lungs.

Moderate evidence: Deposited dose is a modeled physical mass estimate, not a measured systemic or biological dose; single-lab study of 10 products, one 1-minute exposure event per product.

Source: Nazarenko 2014, Environmental Science: Nano Link to this fact

Indoor air / Measured in people or real products

Two silver spray products (a 'nano' and a 'regular' version) were the exception to the head-airways pattern: despite having the lowest total deposited aerosol doses of any product tested (2-4 orders of magnitude below the other 8 sprays), a much larger share of their deposited dose — about 29% and 40% respectively — reached the deep alveolar region of the lungs, versus 7-9.5% for the other 8 sprays.

Moderate evidence: Absolute alveolar doses from these two products were still very small in absolute terms because total exposure was so low; this is a proportional, not absolute, finding.

Source: Nazarenko 2014, Environmental Science: Nano Link to this fact

Indoor air / Measured in people or real products

Not noticing a chemical or fragrance smell in your home or workplace anymore does not mean it is gone: electro-olfactogram recordings show peripheral smell receptors stay measurably responsive to a steady background odor even after conscious perception of it has faded, because habituation happens mainly in the brain, not the nose.

Moderate evidence.

Caveats

Evidence is from small human electrophysiology studies of perception, not from measurements of continued chemical absorption, dose, or health effect; this paper does not address whether continued unnoticed exposure is harmful.

Source: Pellegrino 2017, Physiology & Behavior Industry-funded Link to this fact

Indoor air / Other evidence

For hairspray, deodorant, and eau de toilette sprayed at the head or upper body, about 85% of the sprayed product deposits on hair, skin, or other surfaces and only about 15% stays in the air available for inhalation, as a default in the absence of product-specific measurement.

Moderate evidence.

Caveats

The only cited direct measurement behind a comparable number is a 2012 deodorant/antiperspirant aerosol study (76.5-88.6% available for inhalation, i.e., 11.4-23.5% deposited) — a different, narrower product set than hairspray/eau de toilette.

Source: Steiling et al. 2025, Toxicology Letters Industry-funded Link to this fact

Indoor air / Other evidence

Sprayed cosmetic droplets are mostly gone from the breathing zone within minutes: about 35% clear in the first minute after spraying and about 95% clear within eight minutes, which is why the authors recommend a standard 10-minute exposure duration for modeling.

Moderate evidence: The 35%/95% clearance figures are cited from a single 2021 CIR resource document, not independently replicated here.

Source: Steiling et al. 2025, Toxicology Letters Industry-funded Link to this fact

Indoor air / Measured in people or real products

In controlled chamber testing of 12 cosmetic spray products (sunscreens, dry shampoos, hair sprays, a moisturizing and a setting spray, and perfumes) applied 20 cm from the measurement point, one sunscreen spray reached a maximum PM10 particle-number concentration of 1.03 x 10^6 particles per cubic centimeter, and another reached a maximum PM10 mass concentration of 36.17 mg per cubic meter.

Moderate evidence.

Caveats

Single lab, chamber-based, near-field (20 cm) measurement of the immediate spray plume, not a room-average or personal-exposure measurement; one unit tested per product; no replication by an independent group yet.

Source: Dai et al. 2026, ACS Environmental Au Link to this fact

Indoor air / Measured in people or real products

Propellant-based cosmetic sprays (sunscreen, dry shampoo, hair spray) emitted far more submicron particles than pump-based sprays: the two pump perfumes tested stayed below 100 particles per cubic centimeter across all size fractions, while propellant sprays ranged up to hundreds of thousands of particles per cubic centimeter.

Moderate evidence.

Caveats

12 products from unnamed brands, single lab; propellant vs. pump delivery is confounded with product type (perfumes vs. sunscreens/hair sprays), so the difference cannot be attributed to propellant use alone.

Source: Dai et al. 2026, ACS Environmental Au Link to this fact

Indoor air / Measured in people or real products

Modeling with the Multiple-Path Particle Dosimetry (MPPD) model estimated that a single use of one dry-shampoo spray could deposit up to 1.38 x 10^10 submicron particles in the respiratory tract, mostly by particle count rather than mass (total deposited mass below 50 micrograms), while sunscreen sprays delivered the highest total deposited mass, up to about 2.22 milligrams per use.

Moderate evidence.

Caveats

Deposition doses are model estimates (MPPD), not measured in a human airway; the model did not account for hygroscopic particle growth or electrostatic charge, which the authors say makes the net effect on total dose uncertain.

Source: Dai et al. 2026, ACS Environmental Au Link to this fact

Indoor air / Measured in people or real products

Among the 9 air fresheners where diethyl phthalate (DEP) was detected, NRDC's 2007 test found levels ranging from 0.78 ppm to 7,300 ppm, averaging 977 ppm among DEP-containing products.

Moderate evidence: Single lab, single sample per product, not independently replicated.

Source: NRDC 2007, Clearing the Air Link to this fact

Indoor air / Measured in people or real products

At one Taoist temple in Yi-Lan, Taiwan, both particle mass and total PAH content peaked in the submicrometer 0.1-1.0 um size fraction of temple incense-burning particles: 119.0 (SD 35.2) ug/m3 particle mass and 0.19 (SD 0.002) ug/m3 total PAHs, versus 31.0/4.8 ug/m3 particle mass and 0.07/0.02 ug/m3 PAHs for the 1.0-10 um and sub-0.1 um fractions.

Moderate evidence: Field measurement from a single temple over 13 sampling days (2010); does not generalize to other temples, incense products, or ventilation conditions.

Source: Lin 2012, Science of The Total Environment Link to this fact

Indoor air / Test-chamber measurement

Unscented reference candles emitted far less formaldehyde, benzene, and fragrance chemicals than otherwise-similar scented candles from the same study, across both small and large test chambers.

Moderate evidence: Single-lab dataset; consistent with independent findings from Salthammer 2021 and Andersen 2021 that fragrance, not wax, drives candle combustion byproduct emissions.

Source: Petry 2014, Regulatory Toxicology and Pharmacology Industry-funded Link to this fact

Indoor air / Other evidence

Across 10 real, working New York City nail salons, total VOC levels (measured in real time with a photoionization detector) averaged almost 10 times higher (32 ppm) when indoor CO2 exceeded the ANSI/ASHRAE ventilation target of 850 ppm than when the target was met (4.1 ppm).

Moderate evidence: Small (n=10), non-random convenience sample skewed toward larger, 'upscale' Manhattan salons; TVOC is an unspeciated PID sum, not a specific chemical measurement.

Source: Pavilonis, Roelofs & Blair 2018, Journal of Occupational and Environmental Hygiene Link to this fact

Indoor air / Other evidence

Mean total VOC levels measured in 10 NYC nail salons (12 ppm, median 4.0 ppm, range 0.035-67 ppm) were, in the study authors' own assessment, many times higher than would be considered acceptable in homes or office workplaces.

Moderate evidence: The paper does not give a specific numeric residential/office comparison value in text, only a qualitative 'many times greater' statement; TVOC is unspeciated.

Source: Pavilonis, Roelofs & Blair 2018, Journal of Occupational and Environmental Hygiene Link to this fact

Indoor air / Other evidence

Nail technicians' whole-blood toluene and ethyl acetate rose significantly over a single work shift (toluene 0.16→0.36 µg/L; ethyl acetate <0.16→0.51 µg/L) and post-shift levels significantly exceeded U.S. general-population (NHANES) levels for female nonsmokers.

Moderate evidence: Single small pilot study (n=10); one small cohort does not establish generalizability across the nail-salon industry.

Source: Ceballos et al. 2019, Indoor Air Link to this fact

Indoor air / Other evidence

Better ventilation (higher air changes per hour) was significantly associated with lower personal-air toluene in nail salons (Spearman r=-0.76, p=0.017), but also with higher salon-area methyl methacrylate (r=0.71, p=0.034).

Moderate evidence.

Caveats

Small sample (7 salons); the positive ACH-methyl-methacrylate correlation is the opposite of the expected direction and is only the authors' hypothesis (increased monomer evaporation at higher airflow), not confirmed.

Source: Ceballos et al. 2019, Indoor Air Link to this fact

Indoor air / Test-chamber measurement

Standardizing 196 results from 12 published potted-plant VOC-chamber studies into clean air delivery rate (CADR), the typical (median) houseplant removes VOCs at about 0.023 m3/h, roughly 4,000 times weaker than a standard portable air cleaner (~100 m3/h).

Moderate evidence.

Caveats

Best-case estimate; the underlying mass-balance models assumed negligible chamber leakage and surface sorption, both of which would inflate apparent plant removal, so true removal is likely smaller still.

Source: Cummings & Waring 2020, Journal of Exposure Science & Environmental Epidemiology Link to this fact

Indoor air / Other evidence

To match the VOC removal that ordinary outdoor-to-indoor air exchange already provides in a typical home or office (~1 h-1 air exchange rate), a room would need 10 to 1,000 potted plants per square meter of floor space.

Moderate evidence: Best-case plant-performance assumption (no chamber leakage/sorption); ceiling height held constant at 2.5 m across the analysis.

Source: Cummings & Waring 2020, Journal of Exposure Science & Environmental Epidemiology Link to this fact

Indoor air / Other evidence

Even using the best-performing plants (90th percentile of the dataset) in an unusually airtight building, one potted plant per square meter of floor area (already impractically dense for interior design) achieves only about 20% of the VOC removal that air exchange alone provides.

Moderate evidence: Requires both an unusually low air exchange rate (<0.2 h-1) and the single best-case CADRp tier; falls off quickly at more typical air exchange rates.

Source: Cummings & Waring 2020, Journal of Exposure Science & Environmental Epidemiology Link to this fact

Indoor air / Other evidence

A historical calculation (Levin 1992), using the most generous reading of the early Wolverton/NASA chamber data, found a typical ~140 m2 (1,500 ft2) house would need 680 houseplants (4.9 plants/m2) just to raise plant-driven VOC removal to 0.096 h-1, about an order of magnitude below normal air exchange and called 'obviously not attainable.'

Moderate evidence: Uses the most generous (best-case) early NASA dataset; independently replicated in direction and order of magnitude by this paper's own larger analysis.

Source: Cummings & Waring 2020, citing Levin 1992, Journal of Exposure Science & Environmental Epidemiology Link to this fact

Indoor air / Measured in people or real products

In a field study of two Michigan hotels, hotel housekeepers' and other staff's personal breathing-zone VOC exposure while working (57 ± 36 µg/m3 total target VOCs) was nearly twice the level measured by stationary indoor-area monitors in the same hotels (28 ± 15 µg/m3), and both were far above outdoor levels (mostly below detection).

Moderate evidence: Small sample (2 hotels, 22-23 personal samples); short 6-9 hour sampling shifts; not generalizable to other hotels.

Source: Lin 2021, Indoor Air Link to this fact

Indoor air / Measured in people or real products

Hotel housekeepers' real occupational personal exposure to fragrance terpenes (mainly limonene and alpha-pinene) from direct, repeated contact with cleaning and laundry products averaged just 7.7 µg/m3, even though every cleaning product tested in the study contained terpenes (up to 64 µg/mL in one smoke-removal spray).

Moderate evidence: Occupational, not general-population exposure; short sampling window (6-9h); small sample.

Source: Lin 2021, Indoor Air Link to this fact

Indoor air / Measured in people or real products

In this hotel study, airborne formaldehyde — the single biggest driver of estimated health risk — did not track terpene-fragrance levels or season (terpene-ozone secondary chemistry would be expected to rise with summer ozone), leading the authors to attribute it instead to building materials, furnishings, and the large volume of bedding and towels used in hotels, not to the terpene-containing cleaning and laundry products.

Moderate evidence: Attribution is inferential, not source-tested directly; the authors call for further study to verify formaldehyde sources in hotels.

Source: Lin 2021, Indoor Air Link to this fact

Indoor air / Measured in people or real products

In a 2021 pilot study of 20 real nail salons in the NYC area, toluene (median 7.03 ppb) and d-limonene (median 4.21 ppb) were the two most abundant of 31 volatile organic compounds measured in the air, and the authors attribute the d-limonene to cleaning and disinfection products rather than nail products, since d-limonene is not a nail-product ingredient.

Moderate evidence.

Caveats

Small convenience sample (n=20), area/micro-environmental air sampling only (not personal exposure), sampled during COVID-19 when cleaning frequency was likely elevated; source attribution to cleaning products is the authors' inference, not measured (no product-ingredient data collected).

Source: Han et al. 2022 Link to this fact

Indoor air / Measured in people or real products

Nail salons serving 30 or more customers per day had significantly higher air d-limonene (median 6.18 ppb) than salons serving fewer than 30 customers (median 2.30 ppb, p=0.044), consistent with more frequent cleaning of tables between customers.

Moderate evidence: Single small pilot study; cleaning-product use itself was not directly measured or recorded, only inferred from customer volume and observed cleaning behavior.

Source: Han et al. 2022 Link to this fact

Indoor air / Other evidence

Ordinary spray-and-wipe cleaning with quats, bleach, hydrogen peroxide, or a thymol-based botanical disinfectant raised indoor fine-particle (PM2.5) levels by 0.7-14.5 micrograms per cubic meter and total-VOC sensor readings by 10-104 ppbv, measured across a residential bathroom, a university office, two chemistry labs, and a hotel in Canada.

Moderate evidence: Single study, small replicate counts per cleaner/location, and the TVOC sensor is explicitly non-quantitative.

Source: Souza 2025, ACS Earth Space Chem, ACS Earth and Space Chemistry Link to this fact

Indoor air / Other evidence

The lowest-ventilation room tested, a residential bathroom with an air change rate under 1 per hour, showed 146-346% higher cleaning-related PM2.5 increases and about 7-fold higher TVOC increases than a university office and lab with 5.9-9.1 air changes per hour, for the same cleaning products.

Moderate evidence: One bathroom, one office, two labs; not a dose-response series across many ACR values.

Source: Souza 2025, ACS Earth Space Chem, ACS Earth and Space Chemistry Link to this fact

Indoor air / Other evidence

The particulate matter released during cleaning in this study looked like direct, mechanical spray-bottle emission rather than new particles forming from chemical reactions in the air, consistent across all four very different cleaning chemistries tested.

Moderate evidence.

Caveats

No ozone was deliberately added or measured in these experiments, and none of the four products was a terpene-rich scented cleaner, so this does not rule out secondary particle formation under different (ozone-rich, terpene-rich) conditions documented elsewhere.

Source: Souza 2025, ACS Earth Space Chem, ACS Earth and Space Chemistry Link to this fact

Indoor air / Other evidence

Bleach cleaning produced a two-humped (bimodal) rise in total VOC readings, a pattern consistent with bleach's chlorine-based oxidants reacting with ordinary indoor VOCs to form new, oxidized compounds, rather than only releasing VOCs directly.

Moderate evidence: The oxidized compounds were not chemically identified in this study; the PID gives only a total, non-specific VOC signal, so this is an inferred mechanism, not a confirmed one.

Source: Souza 2025, ACS Earth Space Chem, ACS Earth and Space Chemistry Link to this fact

Indoor air / Other evidence

During real COVID-19 disinfection at a hotel, repeated use of a quats-based disinfectant raised fine-particle levels by 5.5 to 14.2 micrograms per cubic meter in the lobby, elevator, and a public bathroom, exposing cleaning staff to repeated particle bumps throughout a work shift.

Moderate evidence.

Caveats

One day of field measurement, one hotel; cleaning protocol there also deviated from the product label (solution left on surfaces rather than wiped off) to reduce staff vapor exposure.

Source: Souza 2025, ACS Earth Space Chem, ACS Earth and Space Chemistry Link to this fact

Indoor air / Other evidence

For 7 of 8 chemicals tracked in feminine hygiene products, a validated toxicokinetic model found that breathing ordinary indoor air contributed more to total monthly body burden than the feminine hygiene products themselves; the one exception was p-cymene, a common fragrance chemical, where product use was the dominant source.

Moderate evidence: Based on a small Michigan indoor-air sample (n=20) and a conservative worst-case dermal model; may not generalize to other regions or housing stocks.

Source: Lin 2025, Environmental Health Perspectives Link to this fact

Indoor air / Other evidence

In a 1989-era US EPA test house, a suit, skirt, and two blouses fresh from a dry cleaner (perchloroethylene solvent) put about 0.5 to 3 milligrams per cubic meter of the solvent into a closed closet on the first day, and about 60-190 micrograms per cubic meter into the adjoining bedroom.

Moderate evidence: One leased house kept closed, one cleaner, four runs with about 6-fold load-to-load spread; values read off bar charts are approximate; EPA-authored, no industry funding.

Source: Tichenor 1990, Atmospheric Environment. Part A. General Topics Link to this fact

Indoor air / Other evidence

The solvent from freshly dry-cleaned clothes was still detectable in the closet a week later (about 0.15-0.7 mg/m3 on day 7, approx.), and dropped to near or below the detection limit (1 microgram per cubic meter) only after the clothes were removed and the house was ventilated for days.

Moderate evidence: Single closed test house; the authors' closet was sealed with doors closed; approx., read from Fig. 3.

Source: Tichenor 1990, Atmospheric Environment. Part A. General Topics Link to this fact

Indoor air / Other evidence

In a room-sized test chamber with ozone at about 126 ppb, one spray of a lime-scented liquid air freshener released scent chemicals (mostly limonene) that reacted with the ozone and added about 200 micrograms per cubic meter of fine particles, up from a starting level of 13.

Moderate evidence.

Caveats

Single unreplicated chamber run (11 m3) with a generator-set ozone level and a direct spray; particle mass is calculated from particle counts, not weighed. Replicated by other chamber groups for the same mechanism, but this exact number is one run.

Source: Sarwar 2004, Journal of the Air & Waste Management Association Link to this fact

Indoor air / Other evidence

A pine-scented solid (hanging) air freshener in a chamber with about 112 ppb ozone added about 110 micrograms per cubic meter of fine particles, averaging about 81 over a 4-hour-plus run; with ozone at 3 ppb it added almost nothing.

Moderate evidence: One run per ozone level in an 11 m3 chamber; the authors link this to car fresheners hung from mirrors but did not test a vehicle.

Source: Sarwar 2004, Journal of the Air & Waste Management Association Link to this fact

Indoor air / Other evidence

The same scented products made far fewer new particles when ozone was low (3-15 ppb): added particle mass fell to 0.1-12 micrograms per cubic meter, though the liquid air freshener still made about 5.5 at 15 ppb.

Moderate evidence.

Caveats

Low- and high-ozone runs also differed in how much product was released (the liquid freshener released about a third as much in the low-ozone run) and in air exchange, so ozone is not isolated. Single runs.

Source: Sarwar 2004, Journal of the Air & Waste Management Association Link to this fact

Indoor air / Other evidence

A lemon-scented general-purpose cleaner, a wood floor cleaner, and a perfume sprayed into a chamber with 95-219 ppb ozone added about 16, 70, and 22 micrograms per cubic meter of fine particles, much less than the air fresheners.

Moderate evidence: Single chamber runs; the floor cleaner run used the highest ozone (219 ppb) so it is not comparable with the others; particle mass modeled from counts.

Source: Sarwar 2004, Journal of the Air & Waste Management Association Link to this fact

Indoor air / Other evidence

A 2011 Georgetown study that sent test fabrics through seven Northern Virginia dry cleaners found perchloroethylene (PCE) solvent still in polyester, wool, and cotton after one cleaning at all five shops that use PCE, about 10-57 nmol/cm2 depending on fabric and shop.

Moderate evidence.

Caveats

One jacket and one cleaning per shop, unpressed swatches sewn into the lining, seven shops in one region; residue measured, not what anyone breathes or absorbs. No industry funding stated.

Source: Sherlach 2011, Environmental Toxicology and Chemistry Link to this fact

Indoor air / Measured in people or real products

MI used as a paint preservative can reach people through the air: one quarter of MI-allergic patients with an identified source traced to paint, and the authors note people may be exposed unexpectedly in public spaces and shops.

Moderate evidence: Paint exposure was identified by case review and product data sheets, not air measurements in this paper; the airborne route rests on case reports cited by the authors.

Source: Lundov 2013, Contact Dermatitis Link to this fact

Indoor air / Other evidence

In a 2001-2003 New York City study of 126 households, people living in buildings with a perchloroethylene dry cleaner had median indoor air of 27.5 micrograms per cubic meter, versus 2.3 in nearby buildings without one, and median adult blood levels of 0.15 versus 0.02 ng/mL.

Moderate evidence.

Caveats

One city, one study group; dry-cleaner buildings were deliberately selected from minority, low-income and complaint buildings, so this is not a city-wide average; one-day air samples; US EPA-funded, no industry link.

Source: Storm 2013, Environmental Research Link to this fact

Indoor air / Other evidence

Indoor air perchloroethylene was the dominant predictor of a person's blood and breath levels in dry-cleaner buildings; once air level was accounted for, age, sex, race/ethnicity, and income did not significantly predict them.

Moderate evidence: Regression in 74-79 people in dry-cleaner buildings only; one-day air sample versus blood drawn on average about 26 days later at a clinic.

Source: Storm 2013, Environmental Research Link to this fact

Indoor air / Other evidence

In the fragrance industry's 2015 aggregate exposure model, perfume, body spray, and deodorant spray were counted only as skin exposure; the paper reports no figure for how much is breathed in when a spray is used on the body.

Moderate evidence: Industry-funded paper by RIFM, Unilever, P&G, Givaudan and Firmenich staff; it shows the model did not estimate inhalation, not that inhalation is large or small.

Source: Safford et al. 2015, Regulatory Toxicology and Pharmacology Industry-funded Link to this fact

Indoor air / Review of other studies

Only four studies have ever measured how much perc is left in dry-cleaned clothes, and none looked at knitted outer garments, blended fabrics, or bedding, according to a 2016 review.

Moderate evidence.

Caveats

Secondary review funded by Australian Wool Innovation (wool industry body); 'systematic' is a self-label with no study counts or appraisal; relies on agency, trade and manufacturer sources. A narrative search (English only, searched 2013 and 2016); studies published since are not covered.

Source: Troynikov 2016, Journal of Environmental Management Industry-funded Link to this fact

Indoor air / Review of other studies

Perc vapor can seep through walls and ceilings into homes next to dry cleaners, and clothes that come out of the machine under-dried can expose customers, a 2016 review notes.

Moderate evidence.

Caveats

Secondary review funded by Australian Wool Innovation (wool industry body); 'systematic' is a self-label with no study counts or appraisal; relies on agency, trade and manufacturer sources. Mechanism statement from secondary sources; no levels given in this review. Measured home levels are in the Storm 2013 and Chao 1998 pages.

Source: Troynikov 2016, Journal of Environmental Management Industry-funded Link to this fact

Indoor air / Measured in people or real products

In four Polish spa salons, air sampled after aromatherapy massages exceeded the 300 µg/m³ indoor TVOC target in nearly every case, and one salon reached about 23,700 µg/m³ after a single massage.

Moderate evidence: 60 grab samples in four salons, one season; the 300 µg/m³ figure is a comfort target, not a health limit; the peak was a single instantaneous sample, not an 8-hour average.

Source: Pytel 2021, Environmental Science and Pollution Research Link to this fact

Indoor air / Measured in people or real products

In those spa salons, terpenes made up about 22% to 86% of the airborne VOC total on the days charted, and limonene was the most abundant terpene in all four.

Moderate evidence: Range from one example day per salon (Fig. 3), not all 60 samples; non-limonene VOCs are toluene-equivalent estimates.

Source: Pytel 2021, Environmental Science and Pollution Research Link to this fact

Indoor air / Measured in people or real products

What fills a treatment room's air depends on the oils used: limonene-rich oils such as orange or grapefruit gave limonene-dominated air, while rose oil gave none.

Moderate evidence: Few days per salon, oil mixtures often unknown or blended with additives; association by day, not controlled comparison.

Source: Pytel 2021, Environmental Science and Pollution Research Link to this fact

Information, not medical advice. See also: myths we won’t tell you.